Mounting
Standard Operation
RBC-FDP2-F-PE Interface
SW1
SW7
75.00
FDP2 Configuration Switches
Installation and Operating Instructions
The FDP2 should be
mounted using the
keyhole mounting
points as indicated in
the adjacent diagram.
The FDP2 has a number of standard configurations that can be set using
switches SW1 to SW7 shown above. Factory configuration is configured
with all switches OFF. In this mode the FDP2 operates as a standard fault
monitoring device. Additional preset modes are available using SW1 and
SW2 to operate the system in preset Heat, Cool and Auto modes*.
Ø 4.00
13.00
Fault
Ø 4.00
The FDP can be
mounted horizontally
or vertically.
Fault Monitoring
No Fault
Ø 9.00
20.00
26.00
72.00
FDP2-F
Fault Interface
8 Units max
TCC-NET
D-BUS
RELAY
R1
R2
Ø 9.00
A
D1
B
D2
C
ON
ON
RealTime Control Systems Ltd
FDP2 Model 9410-2-A6
SW1
SW7
Basic Cable Installation
Cabling should be a minimum 0.75mm2 throughout. Terminals TCC-NET
A/B connect to the Toshiba TCC-NET. TCC-NET installation should follow
Toshiba installation specifications. Terminals R1-R2 connect to fault
monitoring or indication equipment according to the specified rating of the
relay. The FDP2 is powered from the TCC-NET and requires no extra power
supply.
63.00
87.00
Fault Monitoring + Locked Cooling Preset
18.60
Indoor Unit
18
8 Units max
ALL DIMENSIONS IN MM
NOT TO SCALE
TCC-NET
D-BUS
RELAY
R1
R2
A
D1
D2
B
C
FDP2 Description
The FDP2-F is a monitoring and control interface for the Toshiba Digital
Inverter, SHRM and SMMS range of air-conditioners.
TCC-NET
To fault monitoring
Fault Reporting
A
B
The FDP2-F Interface detects all indoor and outdoor faults occurring in
TCC-NET compatible Toshiba air-conditioners and reports them by closing
relay contacts R1-R2. The FDP2-F is connected on the TCC-NET network
with or without a standard remote controller and detects any faults that can
be displayed on the controller for up to 8 units. Red and Green LEDs
Indicate Fault/No Fault state.
Fault Monitoring + Locked Heating Preset
23
Toshiba Remote Controller
8 Units max
Key:
LED Functionality
OFF
FLASHING
ON
Control Functions
Normal Operation
GROUP CONTROL. Multiple FDP2 Interfaces can be connected to form
large groups of units controlled from a single remote controller.
R
G
R
Power-Up sequence
Factory Configuration
No Fault State
Unit Fault
G
OPERATION PRESETS. Remote controller operation can be locked and
various different preset run conditions can be sent from the FDP2.
R
G
R
G
Power-Up sequence
Custom Configuration
Fault Monitoring + Locked Auto Preset
DUTY/STANDBY. Pairs of FDPs can operate duty/standby control with 24
hour alternating duty, and changeover on fault.
TCC-NET Holdoff. After
power-up and during
unit configuration
R
G
21
HARDWIRED CONTROL. In conjuntion with an FDP2-BMS unit control can
be achieved through potentiometer and volt-free contact inputs as well as
via BMS integration.
8 Units max
Error Conditions
R
G
Device configuration error
CUSTOM CONTROL. FDP2 interfaces can be supplied in custom
configurations to suit specific applications.
R
G
No unit master found on TCC-Net
R
G
D-BUS Communications timeout
Duplicate D-BUS Address detected
Warnings and Cautions
R
G
Do not exceed the specified fault relay ratings
*Units that do not support specific modes such as cooling-only units will operate in fan-only in unsupported
modes.
|
Telex Network Card NI 223 Plus User Manual
Thermador Dishwasher DWHD94BF User Manual
Trane Heating System TSC060 120 50 Hz User Manual
Tricity Bendix Cooktop SB411 User Manual
Tricity Bendix Cooktop SIE553 User Manual
Uniden Cordless Telephone D17882 User Manual
Uniden Scanner USC 2500XL T User Manual
ViewSonic Computer Monitor E70f+ User Manual
Wayne Water Pump 550100 001 User Manual
Weber Gas Grill 56069 User Manual